Command 0002 (Get Settings)

Start  Zurück  Weiter

Client requests settings important for the PDA-Client

 

Client request:

+-------+-+-----------+-------+

|0 0 0 2|0|0 0 0 0 1 5|0 0 0 2|

+-------+-+-----------+-------+

 

Server answer:

3 datafields separated with TAB (ASCII 9)

 

1.) Jobs need confirmation   '0'=No '1'=Yes

2.) Employee prefix, used for reading barcodes

3.) Job prefix, used for reading barcodes

 

 

Jobs need no confirmation, employee prefix is "P" and job prefix is "A"

 

+-------+-+-----------+---------+-------+

|0 0 0 2|1|0 0 0 0 2 0|0 ¤ P ¤ A|0 0 0 2|

+-------+-+-----------+---------+-------+